TEX-E, TEX-ECEW3, TEX-ELZ |
 |
 |
As of April 12, 2011
| Organization |
Requirements
Standard No.*1 |
Cert. No. |
Rating |
Model: UL Style No. |
| UL |
UL 2353
UL 1950-3e/IEC 60950, Annex U
(UL 1411,UL 60950-1) |
E206440
OBJT2
(E188643,AVLV2)*2
(E157568,OCDT2)*2 |
1000 Vrms
TEX-E
B(130°C)*3
TEX-ELZ,
TEX-ECEW3
E(120°C)
|
TEX-E (Style 10348)*2
TEX-ELZ (Style 10349)*2
TEX-ECEW3(Style 10389)*2 |
CSA
(NRTL/C) |
CAN/CSA 60065-03 incl. AM1
ANSI/UL std No. 60065-2007
CAN/CSA-C22.2 No. 60950-1-07
ANSI/UL std No. 60950-1-2007 |
Master Contract
185274*4(LR104155) |
1000 Vrms
120°C(E) |
TEX-E
TEX-ELZ
TEX-ECEW3 |
TUV
Rheinland |
EN 60950-1:2006+A11,
IEC 60950-1:2005
DIN EN 60950-1:2006+A11
EN 60065:2002+A1+A11
IEC 60065:2001+A1 |
T9251520 |
1000 Vrms
TEX-E
B(130°C)
TEX-ELZ,
TEX-ECEW3
E(120°C) |
TEX-E
TEX-ELZ
TEX-ECEW3 |
| BSI |
BS EN 60065:2002,
IEC 60065:2001
Subclauses 14.3.4/14.3.5 (8.8 and 8.17), 10.3 and Annex H; and 20.1.4
BS EN 60950-1:2006,
IEC 60950-1:2005
Subclause 2.9.1 (with 2.9.2 and 5.2.2) and 2.10.5.12 (Annex U); and
4.7.3.4 (A.2 excluding A.2.4, but including A.2.7) |
KM 36738 |
1000 Vrms
120°C |
TEX-E |
| NEMKO |
Annex
U of EN
60950-1:2006; A11 and Annex
H of EN
60065:2002; A1; A11 |
P10212368 |
1000 Vrms
E(120℃) |
TEX-E
TEX-ELZ
TEX-ECEW3 |
| VDE |
DIN EN 60950-1:2006
+A11 (VDE0805Teil1+A11):
2009-11;
EN60950-1:2006+A11:2009-03, IEC60950-1 (ed.2) |
VDE-Reg.-Nr.6735 |
1000 Vpeak
700 Veff
Max. 500kHz
Class E and B |
TEX-E |
| *1 |
TEX-E series are the
insulated winding wire having Reinforced Insulation complying with
subclause 2.10.5.4, Annex U of IEC 60950 3rd, IEC 60950-1 and subclause
8.17, Annex H of IEC 60065 7th. Normal Withstand Test Voltage is 3kVrms
for 1 minute. TEX-E series also complies with 6kVrms for 1minute as a
twisted pair. |
| *2 |
UL changed the category of TEX-E
series from OCDT2, AVLV2 to OBJT2. Therefore, TEX-E wires acquired new
UL File No and the category. The product covered by E206440 (OBJT2) is
quite the same as the product covered by E157568 (OCDT2) and E188643
(AVLV2). These product can be used compatibly each other. |
| *3 |
When operation temperatures of the
wound components exceed Class A (105°C), it is
required in accordance with appropriated Insulation System UL 1446/IEC
61857 regardless of temperature rating of each materials/wires. |
| *4 |
Numbering system of CSA was revised
at 2000. Legacy File number is compatible. |
Note
TEX-E: Standard type, TEX-ELZ: Litz wire type, TEX-ECEW3: Self-bonding
type |
 |
 |
As of April 12, 2011
| Organization |
Requirements Standard No.*1 |
Cert. No. |
Rating |
Models |
| UL |
UL 2353
UL 1950-3e/IEC 60950, Annex U |
E206440,OBJT2 |
Supplementary
Insulation
354Vpeak or DC
120°C(E)*2 |
FWX-E |
| CSA NRTL/C |
CAN/CSA 60065-03 incl. AM1
ANSI/UL std No. 60065-2007
CAN/CSA-C22.2 No. 60950-1-07
ANSI/UL std No. 60950-1-2007
IEC 60065:2001, AM1:2006, AM2:2010
IEC 60950:2005 (2nd Ed), A1:2009
EN 60950-1:2006, A11:2009 |
185274 |
Supplementary
Insulation
354Vpeak or DC
120°C(E) |
FWX-E |
| VDE |
DIN
EN 60950-1:2006 + A11
(VDE 0805Teil 1+A11):2009-11;
EN 60950-1:2006 + A11:2009-03,
IEC60950-1 (ed.2)
DIN EN 60065
(VDE 0860):2009-07
EN 60065:2002 + A1:2006
+ A11:2008-11,
IEC 60065:2001, modified + A1:2005, modified |
VDE-Reg.-Nr.139405 |
Supplementary
Insulation
420Vpeak or DC Class "E" |
FWX-E |
| NEMKO |
Annex
U of EN
60950-1:2006;A11 and Annex H
of EN
60065:2002; A1; A11 |
No. P05204576 |
Supplementary
Insulation
354Vpeak or DC
120°C (E) |
FWX-E |
| *1 |
FWX-E is an insulated
winding wire for Telecommunication Network Voltage circuits and is
recognized as Supplementary Insulation complied with 2.10.5.4, Annex U
of IEC 60950 3rd, IEC 60950-1 and subclause 8.17, Annex H of IEC 60065
7th. Normal Withstand Test Voltage is 1.5kVrms for 1 minute. FWX-E also
complies with 3kVrms for 1minute as a twisted pair. |
| *2 |
When operation temperatures of the
wound components exceed Class A (105°C), it is
required in accordance with appropriated Insulation System UL 1446/IEC
61857 regardless of temperature rating of each materials/wires. |
| *3 |
NEMKO numbering might be renewed
for update standards in future. |
 |
 |
As of April 12, 2011
| Organization |
Requirements Standard No.*1 |
Cert. No. |
Rating |
Models |
| UL |
UL 2353
UL 1950-3e/IEC 60950,
Annex U |
E206440
OBJT2
(E157568, OCDT2)*2 |
Basic Insulation
354Vpeak or DC
E (120°C)*3 |
FSX-E |
| CSA NRTL/C |
CAN/CSA-C22.2 No. 60950-1-07
ANSI/UL 660950-1:2nd Ed.
CAN/CSA-C22.2 No. 60065-03, AM1
ANSI/UL 60065-2007
IEC 60065:2001, AM1:2006, AM2:2010
IEC 60950:2005 (2nd Ed), A1:2009
EN 60950-1:2006, A11:2009 |
185274 (LR104155)*4 |
Basic Insulation
354Vpeak or DC
120°C(E) |
FSX-E |
| VDE |
DIN EN 60950-1:2006 + A11
(VDE 0805Teil 1+A11):2009-11;
EN 60950-1:2006 + A11:2009-03,
IEC60950-1 (ed.2)
DIN EN 60065
(VDE 0860):2009-07
EN 60065:2002 + A1:2006
+ A11:2008-11,
IEC 60065:2001, modified + A1:2005, modified |
VDE-Reg.-Nr.123079 |
Basic Insulation
420Vpeak or DC
Max. 500kHz
Class "E" |
FSX-E |
| *1 |
FSX-E is an insulated
winding wire for Telecommunication Network Voltage circuits and is
recognized as Basic Insulation complied with 2.10.5.4, Annex U of IEC
60950 3rd, IEC 60950-1 and subclause 8.17, Annex H of IEC 60065 7th.
Normal Withstand Test Voltage is 1.5kVrms for 1 minute. FSX-E also
complies with 3kVrms for 1minute as a twisted pair. |
| *2 |
UL changed the category of FSX-E
from OCDT2 to OBJT2. Therefore, FSX-E wire acquired new UL File No and
the category. The product covered by E206440 (OBJT2) is quite the same
as the product covered by E157568 (OCDT2). These product can be used
compatibly each other. |
| *3 |
When operation temperatures of the
wound components exceed Class A (105°C), it is
required in accordance with appropriated Insulation System UL 1446/IEC
61857 regardless of temperature rating of each materials/wires. |
| *4 |
Numbering system of CSA was revised
at 2000. |
|
|
|