Home of Furukawa Electric   SitemapHome
Insulated Winding Wires
Line up of ProductsTech SupportSafety StdSales NetworkConfort Info
  Safety & Reliability Approvals Index of Safety Std

Applicable Safety Codes


TEX-E, TEX-ECEW3, TEX-ELZ Linkage with Authorities
As of April 21, 2014
Organization Requirements
Standard No.*1
Cert. No.*2 Rating Model: UL Style No.
UL UL 2353
UL 1950/IEC 60950-1, Annex U
(UL 1411,UL 60950-1)
E206440,OBJT2 1000 Vrms
Class B*3
TEX-E
TEX-ELZ
TEX-ECEW3
CSA
(NRTL/C)
CAN/CSA 60065-03 incl. AM1
ANSI/UL Std No. 60065-2007
CAN/CSA-C22.2 No. 60950-1-07
ANSI/UL 60950-1 2nd ed.
Master Contract
185274
(LR104155)
1000 Vrms
Class B
TEX-E
TEX-ELZ
TEX-ECEW3
TUV
Rheinland
EN 60950-1:2006+A11+A1+A12
IEC 60950-1:2005+A1
DIN EN 60950-1:2011+A12
IEC 60065:2001+A1+A2
EN 60065:2002+A1+A11+A2+A12
T9251520 1000 Vrms
Class B
500kHz
TEX-E
TEX-ELZ
TEX-ECEW3
BSI BS EN 60065: 2002
IEC 60065: 2001
BS EN 60950-1:2006
IEC 60950-1:2005
KM 36738 1000 Vrms
Class E
TEX-E
NEMKO EN 60065:2002;A1;A11;A2;A12
EN 60950-1:2006;A11;A1;A12
P10212368/A4 1000 Vrms
Class E
TEX-E
TEX-ELZ
TEX-ECEW3
VDE DIN EN 60950-1
(VDE 0805Teil 1):2011-01; EN60950-1:2006+A11:2009+A1:2010
DIN EN 60950-1/A12
(VDE 0805-1/A12): 2011-08;
EN 60950-1/A12:2011-02
IEC60950-1 ed.2; am1
DIN EN 60065 (VDE 0860):2011-10;
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12
IEC 60065:2001 + A1:2005 + A2:2010
DIN EN 60601-1 (VDE 0750, Teil 1):2007-07
EN 60601-1:2006-10
IEC 60601-1 (ed. 3)
6735
 (TEX-E)

40032438 (TEX-ELZ)
500kHz
Class B

1000 Vrms
 (IEC 60950, IEC 60065)

250 Vrms
(IEC 60601, except for 150Vrms for Two MOPP) 
TEX-E

*1 TEX-E series are the insulated winding wire having Reinforced Insulation complying with subclause 2.10.5.12, Annex U of IEC 60950-1 2nd and subclause 8.17, Annex H of IEC 60065 7th. Normal Withstand Test Voltage is 3kVrms for 1 minute. TEX-E series also complies with 6kVrms for 1minute as a twisted pair.
*2 The certificate number will be revised accoring to updating certificate .
*3 When operation temperatures of the wound components exceed Class A (105°C), it is required in accordance with appropriated Insulation System UL 1446/IEC 61857 regardless of temperature rating of each materials/wires.

Note
TEX-E: Standard type, TEX-ELZ: Litz wire type, TEX-ECEW3: Self-bonding type

Back Top


 FWX-E Linkage with Authorities
As of April 26, 2014
Organization Requirements Standard No.*1 Cert. No.*2 Rating Models
UL UL 2353
UL 1950-3e/IEC 60950, Annex U
E206440,OBJT2 Supplementary
Insulation
354Vpeak or DC
120°C(E)*3
FWX-E
CSA NRTL/C CAN/CSA 60065-03 incl. AM1
ANSI/UL std No. 60065-2007
CAN/CSA-C22.2 No. 60950-1-07
ANSI/UL std No. 60950-1-2007
IEC 60065:2001, AM1:2006, AM2:2010
IEC 60950:2005 (2nd Ed), A1:2009
EN 60950-1:2006, A11:2009
Master Contract
185274
(LR104155)
Supplementary
Insulation
354Vpeak or DC
120°C(E)
FWX-E
VDE DIN EN 60950-1
 (VDE 0805 Teil 1):2011-11-01;
EN 60950-1:2006 + A11:2009
 + A1: 2010
DIN EN 60950-1/A12
 (VDE 0805-1/A12):2011-08;
EN 60950-1/A12:2011-02
IEC60950-1 (ed.2);am1

DIN EN 60065
(VDE 0860):2009-07
EN 60065:2002 + A1:2006
 + A11:2008-11
IEC 60065:2001, modified + A1:2005, modified
139405 Supplementary
Insulation
420Vpeak or DC Class "E"
FWX-E
NEMKO EN 60065:2002;A1;A11;A2;A12
EN 60950-1:2006;A11;A1;A12
P05204576/A1 Supplementary
Insulation
354Vpeak or DC
120°C (E)
FWX-E

*1 FWX-E is an insulated winding wire for Telecommunication Network Voltage circuits and is recognized as Supplementary Insulation complied with 2.10.5.12, Annex U of IEC 60950-1 2nd and subclause 8.17, Annex H of IEC 60065 7th. Normal Withstand Test Voltage is 1.5kVrms for 1 minute. FWX-E also complies with 3kVrms for 1minute as a twisted pair.
*2 The certificate number will be revised accoring to updating certificate .
*3 When operation temperatures of the wound components exceed Class A (105°C), it is required in accordance with appropriated Insulation System UL 1446/IEC 61857 regardless of temperature rating of each materials/wires.

Back Top


 FSX-E Linkage with Authorities
As of April 26, 2014
Organization Requirements Standard No.*1 Cert. No.*2 Rating Models
UL UL 2353
UL 1950-3e/IEC 60950,
Annex U
E206440, OBJT2 Basic Insulation
354Vpeak or DC
E (120°C)*3
FSX-E
CSA NRTL/C CAN/CSA-C22.2 No. 60950-1-07
ANSI/UL 660950-1:2nd Ed.
CAN/CSA-C22.2 No. 60065-03, AM1
ANSI/UL 60065-2007
IEC 60065:2001, AM1:2006, AM2:2010
IEC 60950:2005 (2nd Ed), A1:2009
EN 60950-1:2006, A11:2009
Master Contract
185274
(LR104155-15)
Basic Insulation
354Vpeak or DC
120°C(E)
FSX-E
VDE DIN EN 60950-1
 (VDE 0805 Teil 1):2011-11-01;
EN 60950-1:2006 + A11:2009
 + A1: 2010
DIN EN 60950-1/A12
 (VDE 0805-1/A12):2011-08;
EN 60950-1/A12:2011-02
IEC60950-1 (ed.2);am1

DIN EN 60065
(VDE 0860):2009-07
EN 60065:2002 + A1:2006
 + A11:2008-11
IEC 60065:2001, modified + A1:2005, modified
123079 Basic Insulation
420Vpeak or DC
Max. 500kHz
Class "E"
FSX-E

*1 FSX-E is an insulated winding wire for Telecommunication Network Voltage circuits and is recognized as Basic Insulation complied with 2.10.5.4, Annex U of IEC 60950 3rd, IEC 60950-1 and subclause 8.17, Annex H of IEC 60065 7th. Normal Withstand Test Voltage is 1.5kVrms for 1 minute. FSX-E also complies with 3kVrms for 1minute as a twisted pair.
*2 The certificate number will be revised accoring to updating certificate .
*3 When operation temperatures of the wound components exceed Class A (105°C), it is required in accordance with appropriated Insulation System UL 1446/IEC 61857 regardless of temperature rating of each materials/wires.

Back Top
 