  Safety & Reliability Approvals Index of Safety Std

Applicable Safety Codes


TEX-E, TEX-ECEW3, TEX-ELZ Linkage with Authorities
As of April 12, 2011
Organization Requirements
Standard No.*1
Cert. No. Rating Model: UL Style No.
UL UL 2353
UL 1950-3e/IEC 60950, Annex U
(UL 1411,UL 60950-1)
E206440
OBJT2
(E188643,AVLV2)*2
(E157568,OCDT2)*2
1000 Vrms
TEX-E
B(130°C)
*3

TEX-ELZ,
TEX-ECEW3
E(120°C)
TEX-E (Style 10348)*2
TEX-ELZ (Style 10349)*2
TEX-ECEW3(Style 10389)*2
CSA
(NRTL/C)
CAN/CSA 60065-03 incl. AM1
ANSI/UL std No. 60065-2007
CAN/CSA-C22.2 No. 60950-1-07
ANSI/UL std No. 60950-1-2007
Master Contract
185274*4(LR104155)
1000 Vrms
120°C(E)
TEX-E
TEX-ELZ
TEX-ECEW3
TUV
Rheinland
EN 60950-1:2006+A11,
IEC 60950-1:2005
DIN EN 60950-1:2006+A11
EN 60065:2002+A1+A11
IEC 60065:2001+A1
T9251520 1000 Vrms
TEX-E
B(130°C)

TEX-ELZ,
TEX-ECEW3
E(120°C)
TEX-E
TEX-ELZ
TEX-ECEW3
BSI BS EN 60065:2002,
IEC 60065:2001
Subclauses 14.3.4/14.3.5 (8.8 and 8.17), 10.3 and Annex H; and 20.1.4
BS EN 60950-1:2006,
IEC 60950-1:2005
Subclause 2.9.1 (with 2.9.2 and 5.2.2) and 2.10.5.12 (Annex U); and 4.7.3.4 (A.2 excluding A.2.4, but including A.2.7)
KM 36738 1000 Vrms
120°C
TEX-E
NEMKO Annex U of EN 60950-1:2006; A11 and Annex H of EN 60065:2002; A1; A11 P10212368 1000 Vrms
E(120℃)
TEX-E
TEX-ELZ
TEX-ECEW3
VDE DIN EN 60950-1:2006
+A11 (VDE0805Teil1+A11):
2009-11;
EN60950-1:2006+A11:2009-03, IEC60950-1 (ed.2)
VDE-Reg.-Nr.6735 1000 Vpeak
700 Veff
Max. 500kHz
Class E and B
TEX-E

*1 TEX-E series are the insulated winding wire having Reinforced Insulation complying with subclause 2.10.5.4, Annex U of IEC 60950 3rd, IEC 60950-1 and subclause 8.17, Annex H of IEC 60065 7th. Normal Withstand Test Voltage is 3kVrms for 1 minute. TEX-E series also complies with 6kVrms for 1minute as a twisted pair.
*2 UL changed the category of TEX-E series from OCDT2, AVLV2 to OBJT2. Therefore, TEX-E wires acquired new UL File No and the category. The product covered by E206440 (OBJT2) is quite the same as the product covered by E157568 (OCDT2) and E188643 (AVLV2). These product can be used compatibly each other.
*3 When operation temperatures of the wound components exceed Class A (105°C), it is required in accordance with appropriated Insulation System UL 1446/IEC 61857 regardless of temperature rating of each materials/wires.
*4 Numbering system of CSA was revised at 2000. Legacy File number is compatible.

Note
TEX-E: Standard type, TEX-ELZ: Litz wire type, TEX-ECEW3: Self-bonding type

Back Top


 FWX-E Linkage with Authorities
As of April 12, 2011
Organization Requirements Standard No.*1 Cert. No. Rating Models
UL UL 2353
UL 1950-3e/IEC 60950, Annex U
E206440,OBJT2 Supplementary
Insulation
354Vpeak or DC
120°C(E)*2
FWX-E
CSA NRTL/C CAN/CSA 60065-03 incl. AM1
ANSI/UL std No. 60065-2007
CAN/CSA-C22.2 No. 60950-1-07
ANSI/UL std No. 60950-1-2007
IEC 60065:2001, AM1:2006, AM2:2010
IEC 60950:2005 (2nd Ed), A1:2009
EN 60950-1:2006, A11:2009
185274 Supplementary
Insulation
354Vpeak or DC
120°C(E)
FWX-E
VDE DIN EN 60950-1:2006 + A11
(VDE 0805Teil 1+A11):2009-11;
EN 60950-1:2006 + A11:2009-03,
IEC60950-1 (ed.2)
DIN EN 60065
(VDE 0860):2009-07
EN 60065:2002 + A1:2006
 + A11:2008-11,
IEC 60065:2001, modified + A1:2005, modified
VDE-Reg.-Nr.139405 Supplementary
Insulation
420Vpeak or DC Class "E"
FWX-E
NEMKO Annex U of EN 60950-1:2006;A11 and Annex H of EN 60065:2002; A1; A11 No. P05204576 Supplementary
Insulation
354Vpeak or DC
120°C (E)
FWX-E

*1 FWX-E is an insulated winding wire for Telecommunication Network Voltage circuits and is recognized as Supplementary Insulation complied with 2.10.5.4, Annex U of IEC 60950 3rd, IEC 60950-1 and subclause 8.17, Annex H of IEC 60065 7th. Normal Withstand Test Voltage is 1.5kVrms for 1 minute. FWX-E also complies with 3kVrms for 1minute as a twisted pair.
*2 When operation temperatures of the wound components exceed Class A (105°C), it is required in accordance with appropriated Insulation System UL 1446/IEC 61857 regardless of temperature rating of each materials/wires.
*3 NEMKO numbering might be renewed for update standards in future.

Back Top


 FSX-E Linkage with Authorities
As of April 12, 2011
Organization Requirements Standard No.*1 Cert. No. Rating Models
UL UL 2353
UL 1950-3e/IEC 60950,
Annex U
E206440
OBJT2
(E157568, OCDT2)*2
Basic Insulation
354Vpeak or DC
E (120°C)*3
FSX-E
CSA NRTL/C CAN/CSA-C22.2 No. 60950-1-07
ANSI/UL 660950-1:2nd Ed.
CAN/CSA-C22.2 No. 60065-03, AM1
ANSI/UL 60065-2007
IEC 60065:2001, AM1:2006, AM2:2010
IEC 60950:2005 (2nd Ed), A1:2009
EN 60950-1:2006, A11:2009
185274 (LR104155)*4 Basic Insulation
354Vpeak or DC
120°C(E)
FSX-E
VDE DIN EN 60950-1:2006 + A11
(VDE 0805Teil 1+A11):2009-11;
EN 60950-1:2006 + A11:2009-03,
IEC60950-1 (ed.2)
DIN EN 60065
(VDE 0860):2009-07
EN 60065:2002 + A1:2006
 + A11:2008-11,
IEC 60065:2001, modified + A1:2005, modified
VDE-Reg.-Nr.123079 Basic Insulation
420Vpeak or DC
Max. 500kHz
Class "E"
FSX-E

*1 FSX-E is an insulated winding wire for Telecommunication Network Voltage circuits and is recognized as Basic Insulation complied with 2.10.5.4, Annex U of IEC 60950 3rd, IEC 60950-1 and subclause 8.17, Annex H of IEC 60065 7th. Normal Withstand Test Voltage is 1.5kVrms for 1 minute. FSX-E also complies with 3kVrms for 1minute as a twisted pair.
*2 UL changed the category of FSX-E from OCDT2 to OBJT2. Therefore, FSX-E wire acquired new UL File No and the category. The product covered by E206440 (OBJT2) is quite the same as the product covered by E157568 (OCDT2). These product can be used compatibly each other.
*3 When operation temperatures of the wound components exceed Class A (105°C), it is required in accordance with appropriated Insulation System UL 1446/IEC 61857 regardless of temperature rating of each materials/wires.
*4 Numbering system of CSA was revised at 2000.