Home of Furukawa Electric   SitemapHome
Insulated Winding Wires
Line up of ProductsTech SupportSafety StdSales NetworkContact Info
  Line up of Products Index of Line up of Products

Triple Insulated Wire - TEX-BS

"TEX-BS" is reinforced insulated winding wire with thermal class B. The melt-up issues by soldering are improved and has merit to be easy to strip insulator.

Configuration

Features


Dimensions

Nominal
conductor
diameter
(mm)
Tolerance
(mm)
Typical
overall
diameter
(mm)
Maximum
overall
diameter
(mm)
Maximum
conductor
resistance
(omega/km)
Unit Weight
(kg/km)
0.20 0.008 0.400 0.417 607.6 0.398
0.23 0.008 0.430 0.447 454.5 0.499
0.25 0.008 0.450 0.467 382.5 0.575
0.30 0.010 0.500 0.520 262.9 0.787
0.32 0.010 0.520 0.540 230.0 0.882
0.35 0.010 0.550 0.570 191.2 1.034
0.37 0.010 0.570 0.590 170.6 1.143
0.40 0.010 0.600 0.625 145.3 1.316
0.45 0.010 0.650 0.675 114.2 1.633
0.50 0.010 0.700 0.725 91.43 1.985
0.55 0.020 0.750 0.775 78.15 2.371
0.60 0.020 0.800 0.825 65.26 2.793
0.65 0.020 0.850 0.875 55.31 3.249
0.70 0.020 0.900 0.925 47.47 3.741
0.75 0.020 0.950 0.975 41.19 4.267
0.80 0.020 1.000 1.030 36.08 4.828
0.85 0.020 1.050 1.080 31.87 5.424
0.90 0.020 1.100 1.130 28.35 6.055
0.95 0.020 1.150 1.180 25.38 6.721
1.00 0.030 1.200 1.230 23.33 7.422
(Reference Values)