Home of Furukawa Electric   SitemapHome
Insulated Winding Wires
Line up of ProductsTech SupportSafety StdSales NetworkContact Info
  Line up of Products Index of Line up of Products

Supplementary Insulation Winding Wire FWX-E

Supplementary Insulation Wire "FWX-E" is designed for the application in Telecommunications Network Voltage (TNV) transformers.
  • Neither margin tape nor interlayer tape is required for transformers with FWX-E wires. As a result, even more compact transformers can be designed and produced with higher productivity and at lower cost. Fewer component parts are required for an FWX-E applied transformer assembly, compared to other conventional products.
  • Environmentally friendly transformers which are disassembled and recycled with ease, can more easily be designed using FWX-E.

Product photograph

Features
  1. Conforming to supplementary insulation under IEC and UL
  2. Falling into Thermal Index Class E (120C)*1
  3. Rated at 354V peak or DC of max working voltage
  4. Soldered without any insulation layer bared (stripped)
  5. Having extremely fine conductor diameters of 0.11 to 0.19mm

*1 : The UL certification requires an insulation system in UL 1446 for Class A (105C) or above in operation.



Configuration
Configuration of FWX-E


Dimensions
"FWX-E" is characterized by an extruded insulation layer of heat-resistant modified polyester resin and polyamide resin. This was designed and developed to aid solderability and eliminating the need for stripping and is extruded on UEW (polyurethane wire).

Nominal
conductor
diameter
(mm)
Typical
overall
diameter
(mm)
Maximum
overall
diameter
(mm)
Maximum
conductor
resistance
(omega/km)
Unit Weight
(kg/km)
0.11 0.238 0.276 2071 0.127
0.12 0.250 0.288 1724 0.147
0.13 0.260 0.298 1457 0.167
0.14 0.270 0.308 1248 0.188
0.15 0.280 0.318 1081 0.211
0.16 0.292 0.330 944.5 0.237
0.17 0.302 0.340 832.9 0.262
0.18 0.312 0.350 739.9 0.289
0.19 0.322 0.360 661.6 0.318
(Reference Values)
Note: All the above values are shown just for reference and may differ from batch to batch.